Product Details:
|
Product Name: | Easy Operate Cost-Efficient Microwave Condiments Sterilization Machine | Application: | Dry And Sterilize Food, Medicine, Tobacco, Wood, Etc |
---|---|---|---|
Voltage: | 110V-380V, Or Customized | Type: | Dry Heat Sterilization Equipments |
After Warranty Service:: | Video Technical Support, Online Support, Spare Parts | Feature:: | High Efficiency Drying And Sterilization Machine |
Certification: | CE Certificate | ||
High Light: | 380V Microwave Sterilization Machine,Additives Microwave Sterilization Machine |
Easy Operate Cost-Efficient Microwave Condiments Sterilization Machine
Scope of application:
Microwave sterilization equipment is suitable for the sterilization of various materials in the food field. Such as: condiments, additives, chicken powder, meat products, fish products, seafood, fruit pieces, beans, vegetables, mushrooms, flour, starch, rice flour products, soy products, pickles, braised products, feed, Nutrients and other materials.
Microwave sterilization can be divided into post-packaging sterilization and pre-packaging sterilization. The packaging container cannot be made of metal, and medium materials are required. Generally, plastic flexible packaging or glass is used, and engineering plastics are suitable. In order to prevent the bag from expanding during the microwave sterilization process, the equipment can apply pressure in the working chamber and adopt the back pressure sterilization process, which can prevent the loss of the bag from expanding.
Theory of Microwave Sterilization Equipment
Microwave sterilization is the result of the combined effect of the thermal effect and biological effect of the electromagnetic field. The thermal effect of microwave on bacteria is to change the protein, so that the bacteria lose the conditions for nutrition, reproduction and survival and die.
The biological effect of microwave on bacteria is that the microwave electric field changes the potential distribution of the cell membrane section, affects the concentration of electrons and ions around the cell membrane, and thus changes the permeability of the cell membrane. Therefore, the bacteria are malnourished, unable to metabolize normally, the cell structure and function are disordered, and growth and development are inhibited. And death.
In addition, the nucleic acid RNA and deoxyribonucleic acid DNA that microwave can make bacteria grow normally and stably reproduce is caused by several hydrogen bonds relaxation, breakage and recombination, thereby inducing genetic mutation, or chromosomal aberration or even breakage.
Features of Microwave Sterilization Equipment
1. Low-temperature sterilization maintains nutrients and traditional flavors
Microwave sterilization is sterilization through special thermal and non-thermal effects. Compared with conventional thermal sterilization, the required disinfection and sterilization effect can be obtained at a lower temperature and in a shorter time. Practice has shown that the general sterilization temperature can be achieved at 75-80 ℃. In addition, microwave-treated food can retain more nutrients and flavors such as color, aroma, taste, and shape, and has a puffing effect.
2. Microwave sterilization equipment is pollution-free:
Microwave energy itself does not contaminate food. Microwave has a dual sterilization effect of thermal effect and non-thermal effect, and can sterilize at low temperature. This provides a heat sterilization method for maintaining more nutrients in the food.
3. Simple equipment and advanced technology
Compared with conventional disinfection and sterilization, microwave sterilization equipment does not require boilers, complex piping systems, coal yards and transportation vehicles, etc., as long as the basic conditions of water and electricity are available.
4. Both the surface and the interior are carried out at the same time
Conventional thermal sterilization starts from the surface of the material and then spreads to the interior through heat conduction. There is a temperature difference between inside and outside. In order to maintain the flavor of the food and shorten the processing time, the interior of the food often does not reach enough temperature to affect the sterilization effect.
Technical Specifications
Model | NT-20 | NT-40 | NT-60 |
Working frequency | 2450+50MHz | 2450+50MHz | 2450+50MHz |
Rated input apparent power | ≤25kw | ≤50kw | ≤75kw |
Microwave output power | ≥20kw | ≤40kw | ≤60kw |
Working process temperature | 70-200℃ | 70-200℃ | 70-200℃ |
Equipment cooling mode | Water cooled/air cooled | Water cooled/air cooled | Water cooled/air cooled |
Working time | Continuous 24 hours | Continuous 24 hours | Continuous 24 hours |
Height of importand export material | 40-100mm | 40-100mm | 40-100mm |
Transmission belt height | 600-1000mm | 600-1000mm | 600-1000mm |
Transmission speed | 0-0.45m/min | 0-0.45m/min | 0-0.45m/min |
Dehydration rate | 16-20 kg/h | 30-40 kg/h | 48-60 kg/h |
Overall dimensions | 8640*1220+2200mm | 10960+1500+2200mm | 13200+1500+2200mm |
Conveyor width | 500+100mm | 800+100mm | 800+100mm |
Equipment production steps
Payment terms:
T/T, L/C or other formal import and export payment method
Packing and Shipping:
1. Plastic film as inner packaging
2. Formal export packaging or packaging according to customer requirements
3. Shipping by sea, land or rail.
Choose the best shipping method according to the actual situation or customer requirements
FAQ
Q: How long is your production cycle?
A: Usually 7-25 working days, depending on the quantity.
Q: Can you help design the entire process line?
A: Of course, our experienced engineers and technicians can help you arrange the layout and installation of the entire production line according to the actual situation such as your workshop layout.
Q: How to install?
A: Due to the epidemic, we can currently provide online guidance services by experienced engineers.
Q: How is the payment:
A: T/T, L/C or other formal import and export payment method
Q: How long is your warranty period?
A: One year after commissioning is completed.
Q: Will you help us if we have any problems in future production?
A: It is necessary, you can contact me through mobile phone, WhatsApp, etc. We are always at your service. We will help resolve your issue as soon as possible.
Contact Person: Lela
Tel: +8615698008759